Calibration
Hygrometer calibration
Calibrate your humidity measuring devices in our accredited laboratory or at the place of use, under field conditions.
Pressure gauge calibration
Accredited calibration of pressure measuring devices in our laboratory or at the place of use, under field conditions.
Thermometer calibration
Calibrate your temperature measuring devices in our accredited laboratory or at the place of use, under field conditions.
Conductivity calibration
Calibrate your conductivity measurement devices in our laboratory or at the point of use, under field conditions.
pH meter
Calibrate your pH measuring devices in our laboratory or at the point of use, under field conditions.
Dew point calibration
Calibrate your dew point measuring instruments in our laboratory or at the point of use, under field conditions.
Tachometer calibration
Calibrate your tachometers in our laboratory or at the site of use, under field conditions.
Tank scale calibration
Calibrate your tank scale at the point of use, under field conditions.
Airspeed calibration
Calibrate your airspeed measurement devices in our laboratory or at the point of use, under field conditions.
Pressure gauge calibration
Accredited calibration of pressure measuring devices in our laboratory or at the place of use, under field conditions.
We offer our service in a wide range of applications:
- pressure watches, analog manometers
- digital pressure gauges, built-in circuits,
- pressure transmitters with standard electrical output signal (V, mA)
- differential pressure gauges, digital or analog (slanted tube, U-tube gauges, Magnehelic clocks)
- pressure switches
- pneumatic pressure gauges up to 100 bar measurement limit
- hydraulic pressure gauges up to 1000 bar measurement limit
- absolute pressure gauges up to 7 bar measurement limit
- deep vacuum gauges up to a lower measuring limit of 10-4 mbar
- differential pressure transmitters, BMS building monitoring measuring circuits
- barometric pressure gauges
Elsősorban a teljes mérőkör kalibrálását ajánljuk (érzékelő / távadó / kijelző együttesen), igény esetén azonban természetesen a mérőkör egyes elemeinek kalibrálását is vállaljuk.
Az automata kalibrátorokból álló eszközpark lehetővé teszi nagyobb mennyiségű mérőeszközök kalibrálását rövid átfutási idővel.
Thermometer
Calibrate your temperature measuring devices in our accredited laboratory or at the place of use, under field conditions.
We offer our thermometer calibration service in a wide range of applications:
- handheld, portable digital thermometers
- machines, production equipment, equipment, built-in temperature meters, regulators, and recording instruments
- thermometers for laboratory devices (thermostat, refrigerator/freezer, incubator, drying cabinet, liquid baths)
- portable or installed data loggers
- metrics of monitoring systems (EMS/BMS).
- surface thermometers
- infrared thermometers, thermal cameras
We primarily recommend the calibration of the entire measuring circuit (sensor / transmitter / display together), but of course we also undertake the calibration of individual elements of the measuring circuit if required:
- Thermovoltage characteristics of heating elements according to EN 60584-1:2014
- Resistance values of RTD sensors according to EN 60751:2009
- Calibration of transmitters by measuring electrical output signal (V, mA)
- Calibrating displays and measuring loop by simulating the input signal
Calibration range:
- Temperature production between -80 / +400 °C with a metal block, liquid or air thermostat, infrared radiator,
- Temperature production between 400 / 1200 °C with metal block thermostat and infrared radiator.
Humidity sensor
Calibrate your humidity measuring devices in our accredited laboratory or at the place of use, under field conditions.
We offer our hygrometer calibration service in a wide range of applications:
- humidity measuring analog clock, hygrometer
- handheld, portable digital hygrometer
- dry-wet thermometer sensor hygrometer
- temperature and humidity data logger
- humidity measuring transmitter, BMS building monitoring measuring circuits
We primarily recommend the calibration of the entire measuring circuit (sensor / transmitter / display together), but of course we also undertake the calibration of individual elements of the measuring circuit if required.
Our portable humidity generator enables the simultaneous generation of temperature and humidity value pairs, i.e. we perform the calibration at the actual temperature of use!
Conductivity meter
Calibrate your conductivity measurement devices in our laboratory or at the point of use, under field conditions.
Laboratory calibration of a manual conductivity meter with standard solutions, as well as accredited control of the temperature display.
On-site calibration of built-in measuring circuits with a flow-through standard:
- water preparation, water softening systems, water purification devices
- pharmacopoeia quality purified water (PW, WFI) systems
- industrial dishwashers, washing cabinets
- steam generators, distillers
- laboratory and desktop devices
Optional services for calibration:
- display check with resistance decade, simulator
- simulator check of mettler M300 displays with a dedicated calibrator
- specification of measuring devices based on the manufacturer's procedure
pH meter
Calibrate your pH measuring devices in our laboratory or at the point of use, under field conditions.
Calibration of pH measuring devices with standard solutions, as well as accredited control of the temperature display.
On-site calibration of built-in measuring circles:
- water preparation, water softening systems, water purification devices
- pharmacopoeia quality purified water (PW, WFI) systems
- industrial dishwashers, washing cabinets
- manual pH meters
- laboratory and desktop devices
Kalibráláshoz választható szolgáltatások:
- kijelző ellenőrzése szimulátorral
- mérőeszközök pontosítása a gyártói eljárás alapján
Dew point calibration
Calibrate your dew point measuring instruments in our laboratory or at the point of use, under field conditions.
Dew point measuring devices are mainly found when measuring air preparation, compressed air or industrial gases, such as:
- manual dew point gauges
- built-in dew point transmitters, on monitoring systems
- dew point meters connected to the process control of dryers.
The measurement accuracy of dew point gauges changes rapidly for a number of reasons, including improper operation, exposure to dirt and corrosive gases, dew point sensor damage (aging), and electronics drift. With calibration, you can ensure the accuracy of the equipment used to measure the dew point.
Tachometer calibration
Calibrate your tachometers in our laboratory or at the site of use, under field conditions.
The scope of use of tachometer instruments is extremely wide:
- manual tachometer instruments
- rotating units of technology equipment
- mixing elements of tanks
- electric drives, transmissions
- productivity displays of filling and packaging machines
The purpose of speed measurement is to measure the speed of rotating, moving bodies and components during operation and to check their adequacy. Accurate and regular measurements with properly calibrated measuring devices are essential for safe operation during these types of work processes.
Tank scale calibration
Calibrate your tank scale at the point of use, under field conditions.
Typical application of our tank scale calibration service:
- tank scales, weighing cells with mass unit display
- level gauges, dipsticks with volume unit (liter) or level (%) display.
Currently, the calibration service can be realized by filling the storage tank with water as a medium, using a mass flow meter standard, and measuring the filled amount accurately.
Airspeed calibration
Calibrate your airspeed measurement devices in our laboratory or at the point of use, under field conditions.
Air speed measuring instruments (anemometers) measure the air flow speed.
We offer our air speed meter calibration service in a wide range of applications:
- hand-held airspeed instruments with heated fiber or vane sensor
- built-in airflow meters of ventilation systems, technological equipment
- Airspeed meters based on pitot-tube, throttle pressure measurement
- flow meters of clean rooms, laminar equipment
- mobile air volume meters (balometer)
Temperature field calibration
Calibrate the temperature field display at the place of use.
In the case of devices that function by ensuring a specified temperature, it is essential to ensure the accuracy of their control unit. When calibrating the temperature space, the values measured at one or more points of the controlled space are compared with the set or displayed value. During the evaluation, we determine the statistical characteristics, the magnitude of the deviation, the homogeneity and stability of the space.
We offer our temperature field calibration service in a wide range of applications:
- liquid nitrogen storage around -196 °C
- freezers, cryostats
- refrigerators, refrigeration equipment
- thermostats, incubators
- sample containers, temperature-controlled rooms
- water baths, oil baths
- drying cabinets
- autoclave (steam sterilizer)
- hot air sterilization equipment, depyrogenation tunnels
- heat treatment cabinets, test chambers
- high-temperature furnaces, annealing furnaces up to an upper limit of 1200 °C
Flow meter calibration
Calibrate your flow measuring devices in our laboratory or at the point of use, under field conditions.
Flow meters are instruments suitable for measuring the volume or mass of the flow of liquids and gaseous substances when passing through a given cross-section.
The areas of use can be diverse, we calibrate the following:
- floating body flowmeters (rotameters) for liquids, typically water
- built-in flow meters for liquid, typically water media, with a mass flow meter or ultrasonic standard
- gas flowmeters up to a max range of 500 NLM, with air or nitrogen media
- gas flow meter operating in a low measuring range, leakage meters